Plasma_System
-Zepto, Diener electronic
-Vacuum chambers: round with lid (approx. ∅ 105 mm, L 200 mm or L 300 mm)
-Product carrier: Aluminium sheet, stainless steel sheet, borosilicate glass, quartz glass
-Vacuum chambers: round with lid (approx. ∅ 105 mm, L 200 mm or L 300 mm)
-Product carrier: Aluminium sheet, stainless steel sheet, borosilicate glass, quartz glass
Solar Simulator
PECL01,Peccell.
-E-ffective Illumination area: 40×40(mm)
-Spectral match : ≤ ±25% (JIS C 8912 Class A)
-Uniformity : ≤ ±2% (JIS C 8912 Class A)
-Irradiance : 100 mW/cm2 (in the illumination area)
-E-ffective Illumination area: 40×40(mm)
-Spectral match : ≤ ±25% (JIS C 8912 Class A)
-Uniformity : ≤ ±2% (JIS C 8912 Class A)
-Irradiance : 100 mW/cm2 (in the illumination area)
Scanning Electrochemical Microscope(SECM)
-CHI920D,Shanghai Sanjin Import & Export
-A three dimensional nanopositioner
-SECM imaging
-Surface Patterned Conditioning
-Probe Scan Curve
-Probe Approach Curve
-A three dimensional nanopositioner
-SECM imaging
-Surface Patterned Conditioning
-Probe Scan Curve
-Probe Approach Curve
Nano Bead Mill
-JBM-B035, Just Nanotech
-Motor power (Kw): 0.75
-Revolution(rpm): 0~3000
-Volume(L): 0.35
-Material of ceramic parts: SSiC
-Grinding medium size (μm): 30~300
-Motor power (Kw): 0.75
-Revolution(rpm): 0~3000
-Volume(L): 0.35
-Material of ceramic parts: SSiC
-Grinding medium size (μm): 30~300
Temperature and Humidity box desktop constant Operating Instructions
-JeioTech TH-PE-25, HongZhan Group Co,. Ltd.
-Temperature range: 15-90℃
-Humidity range: 30-95%RH
-Internal dimensions: 348×220×353 mm3
-Temperature range: 15-90℃
-Humidity range: 30-95%RH
-Internal dimensions: 348×220×353 mm3
Centrifuge
-Sigma 3K15, SIGMA
-Minimum temperature approx. 5 °C at maximum speed
-Speed range 100 to 15 300 rpm
-Accuracy 1 rpm
-Magnetic rotor identification prevents overspeeding rotors.
-Minimum temperature approx. 5 °C at maximum speed
-Speed range 100 to 15 300 rpm
-Accuracy 1 rpm
-Magnetic rotor identification prevents overspeeding rotors.
Contact Angle Meter
100SB, Sindatek
FTIR Spectroscopy
-Bruker Tensor 27,Hammer Trading Co,.Ltd.
-Equipped with a room temperature DTGS detector
-Mid-IR source (4000 to 400/cm, and a KBr beamsplitter. )
-Maximum resolution is 1/cm
-Equipped with a room temperature DTGS detector
-Mid-IR source (4000 to 400/cm, and a KBr beamsplitter. )
-Maximum resolution is 1/cm
Zeta Potential
-Nanotrac Wave, Just Nanotech
-+/- 200 mV
-Mobility +/-15.5 microns/sec/volt/cm
-Size range 10nm to 20 microns
-+/- 200 mV
-Mobility +/-15.5 microns/sec/volt/cm
-Size range 10nm to 20 microns
UV-visible Spectroscopy
-Perkin Elmer Lambda 35, AI Instruments (Hong Kong) Limit
-Range (nm) : 190–1100
-Double-Beam Operation : Yes
-Bandwidth (nm): 0.5–4 (variable)
-Modes of Operation: Scanning, Wavelength Program, Timedrive, Rate, Quant, Scanning -Quant Applications: Routine UV/Vis testing; Liquids analysis; Solids, pastes and powder samples; Regulatory tests requiring variable bandwidths
-Absorbance Range: 3.2A
-Range (nm) : 190–1100
-Double-Beam Operation : Yes
-Bandwidth (nm): 0.5–4 (variable)
-Modes of Operation: Scanning, Wavelength Program, Timedrive, Rate, Quant, Scanning -Quant Applications: Routine UV/Vis testing; Liquids analysis; Solids, pastes and powder samples; Regulatory tests requiring variable bandwidths
-Absorbance Range: 3.2A
bottom of page